Virtual SFX LabVirtual SFX LabTechnical Guide
Open Studio

Software Reference · 10 October 2026 · 0.36o

Module 3: TBF Pyrotec

The TBF module combines fixture simulation, a virtual desk, proTEC-style controls and a rigging visualization. It is receive-only and has no physical firing or motor-control output.

TBF Models and Selection

Model What the virtual model represents
5-Master proTEC Five outlets and a safety-plus-trigger control layout.
5-Master UpsideDown Flown variant, associated with virtual truss/trim behavior.
Earlier 5-Master A separate model; do not treat its profile as interchangeable with the newer proTEC version.
Single Shot Single-outlet visual with its own activation and fuel assumptions.
Pyromaster Three cartridges plus spark visualization.
Spraymaster Single cartridge/output visual.
Spraymaster Multicolour Three selectable cartridge outputs.
Fountain Flame Combined water/fire appearance with an explicitly assumed channel order.

Choose 3 TBF, add the intended model, then select it before editing TBF Unit. A similar product name does not imply the same footprint, limits or fuel model.

TBF Panel Map

Panel Function
TBF Virtual Desk Per-unit virtual controls and momentary looks.
TBF Unit Model-specific settings, readiness, fuel and connections.
proTEC Control Unit On-screen control-unit emulation and supported program controls.
TBF Rig Trusses, pickups, trim, hoists, limits and performer marks.
Flame Preferences Shared cosmetic flame appearance controls.
TBF Chases Fixture actions and rig movement steps.
TBF Patch Model-specific addressing and conflict inspection.
TBF Guide Reference notes, estimates and unsupported functions.

Use Add Panels to combine these with the shared stage, cues or other modules. Selecting TBF does not require discarding X2 or SQP fixtures.

Unit States, Fuel and Desk

The inspector changes according to the selected model. Check the virtual connection, power, safety/activation state, pressure or cartridge/fuel values and displayed blocking reason before using the desk.

Desk holds operate only the virtual model. Release the hold to end the action; a held trigger does not bypass a readiness gate. Flame Preferences changes the picture, while pressure/fuel/model settings affect the simulation's own estimates.

Cartridge colors and fuel counters are illustrations. Where thresholds, angles or fuel use are marked assumed, the application is choosing a simulation value because a verified device value is not represented.

proTEC Control Unit and Chases

Use the control unit for the supported virtual model and inspect its displayed state before selecting or advancing a program. Its interface does not connect to a real proTEC webserver or device network.

TBF Chases sequences supported fixture actions and truss movement. Edit targets, durations and movement destinations, then preview from a known initial state. A truss-arrival wait delays the next relevant step until the simulated move has reached its condition; it is not confirmation from a real hoist.

TBF also supplies module-aware shared Cue Stack steps for fixture and rig actions. Test mixed-module stacks with output disabled and inspect each module's state rather than assuming a generic cue overrides it.

Truss, Trim and Hoists

  1. Open TBF Rig and add or select a virtual truss.
  2. Set its span, pickup arrangement and supported hoist properties.
  3. Assign compatible flown units and review the height reference.
  4. Change the target trim or drag the truss using its supported handles.
  5. Watch the simulated travel, limit messages and attached units before adding movement to a chase.

Trim normally measures the bottom chord above the deck; the panel can use a top-chord reference. The selected reference changes how you read a number, not the physical meaning of a real rig.

Individual pickups can have different heights or drift, producing rake. The visualization includes a simplified sag model and screening load estimates. Travel can be limited by deck landing clearance, grid/headroom, configured soft limits and the modeled reach of deck-fed fuel hose.

The exported trim sheet is a planning illustration. It is not an engineered rigging calculation, a lifting plan, a structural certification or a motor-controller command.

Performer Marks and Keep-Out Visuals

Place performer markers to compare their positions with the module's drawn keep-out regions and flown effects. A marker turning red is a visualization warning; a marker remaining clear is not a declaration of safety.

The model does not certify wind, heat, fallout, real load-cell readings, dynamic swing, hose behavior or an installed truss. Assumed dimensions and limits remain assumptions even when drawn precisely.

Patch and Exports

TBF footprints vary by model. Use TBF Patch rather than applying an X2 six-channel assumption to every unit. Check overlap across the entire mixed stage.

Shared Vista/MA export packages include module-specific reference rows where supported. These rows document the rehearsal patch; they do not make an unsupported console personality valid automatically.

TBF Persistence and Troubleshooting

The module preserves supported unit and rig configuration in its saved block. Loading a layout resets transient simulation state; it must not overwrite your workspace arrangement or Default Layout 3.4.

Symptom Check
A virtual effect is blocked Selected model, input source, power/connection state, activation/safety state and fuel/pressure estimate.
Flown unit is at the wrong height Assigned truss, pickup positions, trim reference, attachment offset and travel still in progress.
Move stops short Landing/grid limits, soft limits, headroom and hose reach.
Chase appears stalled Arrival-wait step and whether the simulated truss can reach its target.
Profile does not behave as expected Earlier 5-Master versus proTEC/USD variant selection, channel order and assumed thresholds.

TBF PyroTec and Le Maitre do not endorse this module. Consult the relevant real-product and rigging documentation for real-world work.